Regulation 10 fire-door checks explained

The Fire Safety (England) Regulations 2022 introduced specific fire-door information and checking duties in multi-occupied residential buildings. The frequency depends on building height and door type.

2minute guidePublished 7 September 2026
Updated 19 October 2026
01

Buildings above 11 metres

Responsible persons must check communal fire doors at least every three months. Separately, they must use best endeavours to check flat entrance fire doors at least every 12 months and retain records of the steps taken, including unsuccessful access attempts.

  • Plan and record access attempts
  • Keep a complete door asset list
  • Record findings and action defects
  • Retain evidence of completed remedials
02

All multi-occupied residential buildings

For buildings with two or more domestic premises and common escape parts, residents must receive fire-door safety information regardless of height. Give it to new residents as soon as reasonably practicable and repeat it for all residents at intervals not exceeding 12 months.

  • Explain why fire doors must remain closed
  • Tell residents not to tamper with self-closing devices
  • Provide reporting routes for damage
  • Repeat information at least every 12 months and provide it to new residents
03

Routine check versus detailed survey

A routine Regulation 10 check is not necessarily a full technical compliance survey. Escalate uncertain construction, serious damage or missing evidence for competent assessment.

  • Define the inspection level before starting
  • Use consistent defect categories
  • Prioritise risk and access failures
  • Link remedial work back to the inspected asset